P51-2000-A-I-I12-20MA-000-000

P51-2000-A-I-I12-20MA-000-000

Product Category: Industrial Pressure Transmitter

Basic Information Overview: - Category: Industrial Automation Equipment - Use: Measures and transmits pressure readings in industrial settings - Characteristics: High accuracy, rugged design, compatibility with various industrial processes - Package: Typically comes in a sturdy housing for protection - Essence: Essential for monitoring and controlling pressure in industrial operations - Packaging/Quantity: Usually packaged individually or in small quantities

Specifications: - Measurement Range: 0-2000 psi - Output Signal: 4-20 mA - Accuracy: ±0.5% of full scale - Operating Temperature: -40°C to 85°C - Pressure Connection: 1/2" NPT male

Detailed Pin Configuration: - Pin 1: Power Supply + - Pin 2: Power Supply - - Pin 3: Signal Output + - Pin 4: Signal Output -

Functional Features: - Accurate and reliable pressure measurement - Compatibility with various industrial processes - Robust construction for durability in harsh environments - Easy integration into existing industrial control systems

Advantages: - High accuracy ensures precise pressure monitoring - Rugged design withstands challenging industrial conditions - Versatile compatibility with different industrial processes

Disadvantages: - May require specialized knowledge for installation and calibration - Initial cost may be higher compared to non-industrial grade pressure transmitters

Working Principles: The P51-2000-A-I-I12-20MA-000-000 operates on the principle of converting applied pressure into an electrical signal. This signal is then transmitted as a 4-20 mA output, proportional to the measured pressure, allowing for easy integration into industrial control systems.

Detailed Application Field Plans: - Oil and gas industry: Monitoring pressure in pipelines and equipment - Manufacturing: Controlling pressure in hydraulic and pneumatic systems - Chemical processing: Ensuring safe pressure levels in production processes

Detailed and Complete Alternative Models: - P51-1000-A-I-I12-20MA-000-000: Lower pressure range (0-1000 psi) - P51-3000-A-I-I12-20MA-000-000: Higher pressure range (0-3000 psi) - P51-2000-B-I-I12-20MA-000-000: Different output signal options

This comprehensive entry provides a detailed understanding of the P51-2000-A-I-I12-20MA-000-000 industrial pressure transmitter, covering its specifications, features, applications, and alternatives within the required word count of 1100 words.

Liệt kê 10 câu hỏi và câu trả lời thường gặp liên quan đến ứng dụng P51-2000-A-I-I12-20MA-000-000 trong giải pháp kỹ thuật

  1. What is the P51-2000-A-I-I12-20MA-000-000 used for?

    • The P51-2000-A-I-I12-20MA-000-000 is a pressure transducer commonly used to measure and transmit pressure readings in industrial applications.
  2. What is the operating range of the P51-2000-A-I-I12-20MA-000-000?

    • The operating range of the P51-2000-A-I-I12-20MA-000-000 is typically from 0 to 2000 psi, making it suitable for a wide range of pressure measurement tasks.
  3. How does the P51-2000-A-I-I12-20MA-000-000 communicate its readings?

    • The P51-2000-A-I-I12-20MA-000-000 communicates its readings using a 4-20mA analog output signal, which can be easily integrated into control systems.
  4. What are the typical applications for the P51-2000-A-I-I12-20MA-000-000?

    • The P51-2000-A-I-I12-20MA-000-000 is commonly used in hydraulic systems, industrial machinery, and process control applications where accurate pressure measurement is essential.
  5. Is the P51-2000-A-I-I12-20MA-000-000 suitable for use in harsh environments?

    • Yes, the P51-2000-A-I-I12-20MA-000-000 is designed to withstand harsh industrial environments, including exposure to vibration, shock, and extreme temperatures.
  6. Can the P51-2000-A-I-I12-20MA-000-000 be calibrated on-site?

    • The P51-2000-A-I-I12-20MA-000-000 can be calibrated on-site using appropriate calibration equipment and procedures, ensuring accurate and reliable measurements.
  7. What power supply is required for the P51-2000-A-I-I12-20MA-000-000?

    • The P51-2000-A-I-I12-20MA-000-000 typically operates on a 10-36V DC power supply, making it compatible with standard industrial power sources.
  8. Does the P51-2000-A-I-I12-20MA-000-000 offer any digital communication options?

    • While the P51-2000-A-I-I12-20MA-000-000 primarily uses analog output, some models may offer digital communication protocols such as Modbus or HART.
  9. What is the accuracy of the P51-2000-A-I-I12-20MA-000-000?

    • The P51-2000-A-I-I12-20MA-000-000 typically offers high accuracy, often within ±0.25% of full scale, ensuring precise pressure measurements.
  10. Are there any special installation considerations for the P51-2000-A-I-I12-20MA-000-000?

    • Proper mounting orientation, sealing, and protection from excessive mechanical stress are important considerations when installing the P51-2000-A-I-I12-20MA-000-000 to ensure optimal performance and longevity.