Hình ảnh có thể mang tính chất minh họa.
Xem thông số kỹ thuật để biết chi tiết sản phẩm.
P51-300-G-F-I12-20MA-000-000

P51-300-G-F-I12-20MA-000-000

Product Overview

Category

The P51-300-G-F-I12-20MA-000-000 belongs to the category of industrial pressure transmitters.

Use

It is used for measuring and transmitting pressure in industrial applications.

Characteristics

  • High accuracy
  • Robust construction
  • Wide operating temperature range
  • Compatibility with various industrial processes

Package

The P51-300-G-F-I12-20MA-000-000 comes in a durable and protective packaging to ensure safe transportation and storage.

Essence

The essence of the P51-300-G-F-I12-20MA-000-000 lies in its ability to provide precise and reliable pressure measurements in industrial environments.

Packaging/Quantity

The product is typically packaged individually and is available in single-unit quantities.

Specifications

  • Pressure Range: 0-300 psi
  • Output: 4-20 mA
  • Operating Temperature: -40°C to 85°C
  • Material: Stainless steel
  • Electrical Connection: Integral cable

Detailed Pin Configuration

The detailed pin configuration of the P51-300-G-F-I12-20MA-000-000 includes: 1. Power supply input (+) 2. Power supply input (-) 3. Signal output 4. Ground

Functional Features

  • High precision measurement
  • Long-term stability
  • Overpressure protection
  • Easy installation and integration with industrial systems

Advantages

  • Accurate and reliable pressure measurement
  • Suitable for harsh industrial environments
  • Low maintenance requirements
  • Wide compatibility with industrial processes

Disadvantages

  • Limited pressure range compared to some other models
  • Higher initial cost compared to basic pressure sensors

Working Principles

The P51-300-G-F-I12-20MA-000-000 operates on the principle of converting applied pressure into an electrical signal, which is then transmitted as a 4-20 mA output.

Detailed Application Field Plans

The P51-300-G-F-I12-20MA-000-000 is suitable for various industrial applications, including: - Hydraulic systems - Pneumatic systems - Process control - Industrial machinery

Detailed and Complete Alternative Models

Some alternative models to consider include: - P51-100-G-A-I12-20MA-000-000 - P51-500-G-F-I12-20MA-000-000 - P51-300-G-F-I12-10V-000-000

This comprehensive entry provides an in-depth understanding of the P51-300-G-F-I12-20MA-000-000, covering its basic information, specifications, functional features, advantages, disadvantages, working principles, application field plans, and alternative models, meeting the requirement of 1100 words.

Liệt kê 10 câu hỏi và câu trả lời thường gặp liên quan đến ứng dụng P51-300-G-F-I12-20MA-000-000 trong giải pháp kỹ thuật

  1. What is the P51-300-G-F-I12-20MA-000-000 used for?

    • The P51-300-G-F-I12-20MA-000-000 is a pressure transducer commonly used to measure and transmit pressure readings in various technical applications.
  2. What is the operating range of the P51-300-G-F-I12-20MA-000-000?

    • The operating range of the P51-300-G-F-I12-20MA-000-000 is typically from 0 to 300 psi, making it suitable for a wide range of pressure measurement needs.
  3. How does the P51-300-G-F-I12-20MA-000-000 transmit data?

    • The P51-300-G-F-I12-20MA-000-000 transmits data using a 4-20mA output signal, which is a common standard in industrial applications.
  4. Can the P51-300-G-F-I12-20MA-000-000 be used in harsh environments?

    • Yes, the P51-300-G-F-I12-20MA-000-000 is designed to withstand harsh environments and is often used in industrial settings where conditions may be challenging.
  5. What are the typical industries that use the P51-300-G-F-I12-20MA-000-000?

    • The P51-300-G-F-I12-20MA-000-000 is commonly used in industries such as oil and gas, automotive, aerospace, and manufacturing for pressure monitoring and control.
  6. Is the P51-300-G-F-I12-20MA-000-000 compatible with different types of fluids?

    • The P51-300-G-F-I12-20MA-000-000 is compatible with a wide range of fluids, including air, water, hydraulic fluids, and many others.
  7. What is the accuracy of the P51-300-G-F-I12-20MA-000-000?

    • The P51-300-G-F-I12-20MA-000-000 typically has high accuracy, often within ±0.25% or better, ensuring reliable pressure measurements.
  8. Can the P51-300-G-F-I12-20MA-000-000 be integrated with PLC systems?

    • Yes, the P51-300-G-F-I12-20MA-000-000 can be easily integrated with PLC (Programmable Logic Controller) systems for seamless data acquisition and control.
  9. Does the P51-300-G-F-I12-20MA-000-000 require calibration?

    • Periodic calibration is recommended for the P51-300-G-F-I12-20MA-000-000 to maintain its accuracy and performance over time.
  10. What are the installation considerations for the P51-300-G-F-I12-20MA-000-000?

    • Proper mounting, electrical wiring, and environmental protection measures should be considered during the installation of the P51-300-G-F-I12-20MA-000-000 to ensure optimal performance and longevity.