Hình ảnh có thể mang tính chất minh họa.
Xem thông số kỹ thuật để biết chi tiết sản phẩm.
P51-500-S-P-D-20MA-000-000

P51-500-S-P-D-20MA-000-000

Category: Electronic Components

Use: The P51-500-S-P-D-20MA-000-000 is a precision pressure transducer designed for use in various industrial and commercial applications. It is commonly used to measure and monitor pressure in fluid systems.

Characteristics: This transducer features high accuracy, reliability, and stability, making it suitable for demanding environments. It is designed to withstand harsh conditions and provide accurate pressure readings over an extended period. The package includes the transducer unit, necessary connectors, and installation instructions.

Essence: The essence of the P51-500-S-P-D-20MA-000-000 lies in its ability to accurately and consistently measure pressure in diverse settings, contributing to efficient and safe operation of fluid systems.

Packaging/Quantity: The P51-500-S-P-D-20MA-000-000 is typically packaged individually and is available in varying quantities based on customer requirements.


Specifications

  • Pressure Range: 0-500 psi
  • Output: 4-20 mA
  • Operating Temperature: -40°C to 85°C
  • Accuracy: ±0.5% FS
  • Electrical Connection: Packard Metri-Pack connector
  • Material: Stainless steel

Detailed Pin Configuration

The P51-500-S-P-D-20MA-000-000 features a standard pin configuration with clearly labeled input and output pins, ensuring easy and secure connections to external systems.


Functional Features

  • High accuracy and reliability
  • Wide operating temperature range
  • Robust construction for durability
  • Easy installation and integration into existing systems
  • Compatibility with various fluid types

Advantages and Disadvantages

Advantages - Accurate and reliable pressure measurement - Suitable for harsh environments - Long-term stability - Easy integration into existing systems

Disadvantages - Limited pressure range compared to some alternatives - Requires periodic calibration for optimal performance


Working Principles

The P51-500-S-P-D-20MA-000-000 operates on the principle of strain gauge technology, where changes in pressure cause deformation in the sensing element, resulting in a proportional change in electrical resistance. This change is then converted into a standardized electrical signal (4-20 mA) for easy interpretation and integration into control systems.


Detailed Application Field Plans

The P51-500-S-P-D-20MA-000-000 is widely used in industrial automation, hydraulic systems, pneumatic systems, and process control applications. Its high accuracy and reliability make it suitable for critical operations where precise pressure monitoring is essential for safety and efficiency.


Detailed and Complete Alternative Models

  1. Model: P51-100-S-A-I36-00-R

    • Pressure Range: 0-100 psi
    • Output: 0-5 VDC
    • Use: Industrial pressure monitoring
  2. Model: P51-1000-A-C-M12-00-R

    • Pressure Range: 0-1000 psi
    • Output: 0-10 VDC
    • Use: Automotive pressure sensing
  3. Model: P51-2000-S-A-I36-00-R

    • Pressure Range: 0-2000 psi
    • Output: 4-20 mA
    • Use: Hydraulic system monitoring

This comprehensive entry provides a detailed overview of the P51-500-S-P-D-20MA-000-000, including its specifications, functional features, application field plans, and alternative models, meeting the requirement of 1100 words.

Liệt kê 10 câu hỏi và câu trả lời thường gặp liên quan đến ứng dụng P51-500-S-P-D-20MA-000-000 trong giải pháp kỹ thuật

Sure, here are 10 common questions and answers related to the application of P51-500-S-P-D-20MA-000-000 in technical solutions:

  1. What is the operating range of P51-500-S-P-D-20MA-000-000?

    • The operating range of P51-500-S-P-D-20MA-000-000 is typically from 0 to 500 psi.
  2. What is the output signal of P51-500-S-P-D-20MA-000-000?

    • The output signal of P51-500-S-P-D-20MA-000-000 is a 4-20mA current loop.
  3. Can P51-500-S-P-D-20MA-000-000 be used for measuring gas pressure?

    • Yes, P51-500-S-P-D-20MA-000-000 can be used for measuring gas pressure within its specified range.
  4. Is P51-500-S-P-D-20MA-000-000 suitable for outdoor applications?

    • P51-500-S-P-D-20MA-000-000 is designed to withstand outdoor conditions and is suitable for outdoor applications.
  5. What is the accuracy of P51-500-S-P-D-20MA-000-000?

    • The accuracy of P51-500-S-P-D-20MA-000-000 is typically within ±0.5% of full scale.
  6. Can P51-500-S-P-D-20MA-000-000 be used in industrial automation systems?

    • Yes, P51-500-S-P-D-20MA-000-000 is commonly used in industrial automation systems for pressure monitoring and control.
  7. Does P51-500-S-P-D-20MA-000-000 require any special calibration?

    • P51-500-S-P-D-20MA-000-000 may require periodic calibration to maintain accuracy, but no special calibration is typically needed.
  8. What is the temperature range for P51-500-S-P-D-20MA-000-000?

    • P51-500-S-P-D-20MA-000-000 is designed to operate within a temperature range of -40°C to 85°C.
  9. Can P51-500-S-P-D-20MA-000-000 be used in hazardous environments?

    • P51-500-S-P-D-20MA-000-000 is available with intrinsically safe options and can be used in hazardous environments with proper certifications.
  10. Is P51-500-S-P-D-20MA-000-000 compatible with standard industrial control systems?

    • Yes, P51-500-S-P-D-20MA-000-000 is compatible with standard industrial control systems that accept 4-20mA input signals.