The XTR116UA/2K5G4 belongs to the category of precision voltage-to-current converters.
It is used to convert a voltage input signal into a current output signal, making it suitable for various industrial and instrumentation applications.
The XTR116UA/2K5G4 comes in a small outline package (SOIC) with 8 pins.
The essence of the XTR116UA/2K5G4 lies in its ability to accurately convert voltage signals to current signals with high precision and reliability.
The XTR116UA/2K5G4 is typically packaged in reels with a quantity of 2500 units per reel.
The XTR116UA/2K5G4 operates by utilizing a precision operational amplifier and internal feedback loop to accurately convert the input voltage to a corresponding output current. The built-in reference voltage and adjustable output current range allow for flexibility and precise control.
The XTR116UA/2K5G4 is well-suited for applications such as industrial process control, sensor interfaces, test and measurement equipment, and precision instrumentation where accurate voltage-to-current conversion is required.
Some alternative models to the XTR116UA/2K5G4 include the AD693, AD694, and AD695 precision voltage-to-current converters, each offering similar functionality with slight variations in specifications and features.
In conclusion, the XTR116UA/2K5G4 is a precision voltage-to-current converter that offers high accuracy, reliability, and flexibility, making it an ideal choice for various industrial and instrumentation applications.
Word Count: 411
What is the operating temperature range of XTR116UA/2K5G4?
- The operating temperature range of XTR116UA/2K5G4 is -40°C to 125°C.
What is the supply voltage range for XTR116UA/2K5G4?
- The supply voltage range for XTR116UA/2K5G4 is 7V to 40V.
Can XTR116UA/2K5G4 be used in industrial automation applications?
- Yes, XTR116UA/2K5G4 is suitable for industrial automation applications.
Does XTR116UA/2K5G4 support current loop applications?
- Yes, XTR116UA/2K5G4 is designed to support current loop applications.
What is the typical output voltage range of XTR116UA/2K5G4?
- The typical output voltage range of XTR116UA/2K5G4 is 0V to 5V.
Is XTR116UA/2K5G4 compatible with 4-20mA current loops?
- Yes, XTR116UA/2K5G4 is compatible with 4-20mA current loops.
Can XTR116UA/2K5G4 be used in process control systems?
- Yes, XTR116UA/2K5G4 can be used in process control systems.
What is the accuracy of XTR116UA/2K5G4?
- The accuracy of XTR116UA/2K5G4 is typically 0.02% of full scale.
Does XTR116UA/2K5G4 require external calibration?
- No, XTR116UA/2K5G4 does not require external calibration.
Is XTR116UA/2K5G4 RoHS compliant?
- Yes, XTR116UA/2K5G4 is RoHS compliant.